引用本文: |
-
况春艳,卢亮宇,程飚.关节镜下缝线桥技术修复肩袖全层撕裂疗效分析[J].同济大学学报(医学版),2018,39(2):103-106. [点击复制]
- KUANG Chun-yan,LU Liang-yu,CHENG Biao.Efficacy of arthroscopic suture bridge technique for treatment of full-thickness rotator cuff tears[J].同济大学学报(医学版),2018,39(2):103-106. [点击复制]
|
|
摘要: |
目的探讨关节镜下采用缝线桥技术(suture bridge)修复全层肩袖损伤的临床疗效。方法2011年1月至2014年6月,对69例全层肩袖损伤患者予以关节镜下缝线桥技术修复,并对随访结果进行统计学分析。随访24个月,牛津大学肩关节评分(Oxford Shoulder Score, OSS)、美国加州大学肩关节评分系统(University of California at Angeles, UCLA)和Constant-Murley评分表(Constant-Murley Score, CM)评分系统对术后患侧肩关节功能进行评分。结果术后OSS、UCLA和CM评分较术前均明显提高,差异有统计学意义(P<0.05)。前屈、内旋和外旋角度术后24个月随访结果较术前均明显提高,差
异有统计学意义(P<0.05)。但外展角度术后24个月随访结果较术前差异无统计学意义(P>0.05)。VAS和EQ-5D生活质量评分系统(Euro-QoL 5-Dimensions Questionnaire score)术后24个月随访评分较术前均明显提高(P<0.05)。结论肩关节镜下缝线桥技术在修复全层肩袖损伤方面是一种可靠且有效的肩袖修复技术。 |
关键词: 关节镜 全层 肩袖撕裂 缝线桥技术 |
DOI:10.16118/j.1008-0392.2018.02.020 |
投稿时间:2017-07-17 |
基金项目:上海市卫计委项目(20134244) |
|
Efficacy of arthroscopic suture bridge technique for treatment of full-thickness rotator cuff tears |
KUANG Chun-yan,LU Liang-yu,CHENG Biao |
(Dept. of Rehabilitation, East Hospital, Tongji University, Shanghai 200120, China;Dept. of Joint and Sport Medicine, East Hospital, Tongji University, Shanghai 200120, China;Dept. of Orthopedics, Tenth People’s Hospital, Tongji University, Shanghai 200072, China) |
Abstract: |
ObjectiveTo evaluate the clinical efficacy of arthroscopic suture bridge technique for repairing full-thickness rotator cuff tears. MethodsClinical date of 69 patients with full-thickness rotator cuff tear, who were treated with arthroscopic suture bridge technique from January 2011 to June 2014, were retrospectively reviewed. Patients were followed-up for 24 months after surgery, and surgical outcomes were evaluated with Oxford Shoulder Score (OSS), University of California at Angeles (UCLA)and Constant-Murley (CM)scales. ResultsThe OSS, UCLA and CM scores 24 months after surgery were all higher than those before surgery(P<0.05). The means of anteflexion, internal rotation and extorsion angles were better than those before surgery(P<0.05); but there was no significant difference in abduction angles between that before and after surgery.(P>0.05). The means of VAS and EuroQoL 5-Dimensions Questionnaire scores after 24 months follow-up were significantly increased(P<0.05). ConclusionArthroscopical suture bridge is a reliable and effective technique for repairing full-thickness rotator cuff tears. |
Key words: arthroscopy full-thickness rotator cuff tear suture bridge technique |