引用本文
  • 曹立群,赵守亮,杨国标,等.光固化复合树脂在MO洞型中聚合收缩的体外实验研究[J].同济大学学报(医学版),2014,35(1):40-45.    [点击复制]
  • CAO Li-qun,ZHAO Shou-liang,YANG Guo-biao,et al.An in vitro investigation of composite polymerization shrinkage in MO cavities[J].同济大学学报(医学版),2014,35(1):40-45.   [点击复制]
【打印本页】 【在线阅读全文】【下载PDF全文】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 339次   下载 366 本文二维码信息
码上扫一扫!
光固化复合树脂在MO洞型中聚合收缩的体外实验研究
曹立群1,2,赵守亮1,2,杨国标3,倪凡3
0
(1.同济大学附属口腔医院牙体牙髓科,上海200072; 2.同济大学口腔生物医学及转化医学实验室,上海200072;3.同济大学航空与力学学院,上海200092)
摘要:
目的利用电子散斑干涉技术测试临床中常用的5种光固化复合树脂的聚合收缩。方法取15颗新鲜拔除且牙体组织完整、大小相似的下颌第三磨牙,制备MO洞,洞宽为颊舌牙尖距的1/3,洞深为2 mm,然后采用 GRADIA DIRECT-P、Z350、Z250、P60和P90树脂随机充填窝洞(除P90采用其自带的粘接剂,其余都采用G-BOND 粘接剂处理洞壁),在650 mW/cm2光源下,光照固化40 s后采用电子散斑干涉技术对树脂修复体拾面、近中邻面 收缩和牙齿颊面的变形进行测量分析。结果树脂收缩形态与窝洞外形一致,验面最早的收缩条纹出现在MO洞 鸠尾的头部,然后沿着窝洞的方向扩展。近中邻面最早的收缩条纹发生在靠近粘结面处,并向中央扩展。五种树 脂中GRADIADIRECT-P的收缩量最大,P90的收缩量最小。牙齿的颊面条纹首先出现在近中颊尖的牙尖处,并向 远中颊尖扩展。GRADIA DIRECT-P导致的近中颊尖变形量最大,而P90最小。结论电子散斑干涉技术能有效 动态测量树脂修复体聚合收缩和牙齿变形。不同种类的光固化复合树脂,其固化收缩状况和导致的牙齿变形存在着差异。
关键词:  复合树脂  固化收缩  电子散斑干涉技术
DOI:10.3969/j.issnl008-0392.2014.01.009
基金项目:
An in vitro investigation of composite polymerization shrinkage in MO cavities
CAO Li-qun1,2,ZHAO Shou-liang1,2,YANG Guo-biao3,NI Fan3
(1. Dept. of Endodontics, Stomatology Hospital, Tongji University, Shanghai 200072, China;2. Laboratory of Oral Biomedical Science and Translational Medicine, Tongji University, Shanghai 200072, China;University, Shanghai 200092, China;3. School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai 200092, China)
Abstract:
Objective To evaluate the polymerization shrinkage of 5 commercially available dental resin composites using the electronic speckle pattern interferometry (ESPI). Methods Fifteen freshly extracted human mandibular third molars were collected and MO cavities with width of 1/3 of buccolingual cusp distance and depth of 2 mm were prepared in the occlusal surface. Cavities were treated with G-BOND bonding system except for P90 with its own bonding system ; then filled with GRADIA DIRECT-P,Z350,Z250,P60 or P90 respectively,the curing shrinkages of the 5 composites were measured by the ESPI immediately after light cured for 40s under the 650mw/ cm2. Results The shrinkage of the tested composites was fit the shape of the cavities. In the occlusal part, contraction occurred in the head of dovetail firstly and spread along the cavity. In the proximal part, contraction occurred near the bonding interface and spread to the central. Among 5 tested resin composites, GRADIA DIRECT-P showed the largest polymerization shrinkage and P90 showed the minimal. Tooth structure deformation occurred firstly in the adjacent tooth cusp. GRADIA DIRECT-P caused the biggest deformation of the tooth structure,while P90 caused smallest. Conclusion The ESPI can effectively measure polymerization shrinkage of dental resin composites. Different resin composites show difference in polymerization shrinkage and tooth deformation induced.
Key words:  resin composite  polymerization shrinkage  electronic speckle pattern interferometry

您是第5127737位访问者
版权所有《同济大学学报(医学版)》编辑部
主管单位:教育部 主办单位:同济大学
地  址: 上海四平路1239号 邮编:200092 电话:021-65980705 E-mail: yxxb@tongji.edu.cn
本系统由北京勤云科技发展有限公司设计